Confined space assessment
Work through the Confined Spaces Regulations 1997 step by step: is it a confined space, can you avoid entry, is the safe system of work...
- Practical check
- Free
- Review before use
No signup. Use it as a planning aid, then review against the actual site.
Structured scoring
initial → residual
score it live below
Check the detail here, then carry it into the RAMS
This tool helps with one part of the paperwork. The builder brings the task, method, hazards, evidence prompts and sign-off together in the full RAMS draft.
RAMS builder
Choose the work, add site details, answer risk triggers, review gaps and export a PDF draft.
Open the builder →177 templatesTemplate library
Find task-specific RAMS starting points by trade, task, hazard or permit trigger.
Find a template →49 toolsFree tools
Use checkers, permits, calculators and document builders alongside the RAMS workflow.
Use free tools →Is it a confined space?
The 1997 Regulations apply only when both parts of the test are met: the place is substantially enclosed and a specified risk is reasonably foreseeable because of that enclosure.
Document control
Who owns this document and when it gets looked at again — the evidence reviewers check first.
Name, role and company are remembered on this device only — nothing is sent to us.
Next: Location / space assessed
What counts as a confined space
Under the Confined Spaces Regulations 1997 a confined space is defined by two features at once — not just by being small or tight:
- It is substantially enclosed — a chamber, tank, vat, silo, pit, trench, pipe, sewer, flue, well or similar space. It need not be fully sealed.
- Because of that enclosure, a “specified risk” is reasonably foreseeable. The Regulations list five: serious injury from fire or explosion; loss of consciousness from a rise in body temperature (heat); loss of consciousness or asphyxiation from gas, fume, vapour or lack of oxygen; drowning from a rising liquid; and asphyxiation from, or entrapment by, a free-flowing solid such as grain, sand or flour.
Both parts must be present. A loft or a service riser is usually not a confined space — but it can become one if, for example, a leak builds up gas or oxygen is displaced. Manholes, storage tanks, sewers and unventilated chambers commonly qualify, and deep excavations (broadly trenches over about 1.2 m, where heavier-than-air gases can collect) can qualify too. A space's status can change with the contents, the weather and the work being done, so the test is reassessed, not decided once.
If only one part of the test is met, the 1997 Regulations do not apply — but a normal risk assessment under the Management of Health and Safety at Work Regulations 1999 still does.
Why rescue is the part that kills people
HSE is blunt about this: a large share of people who die in confined spaces are not the original entrants but would-be rescuers who go in without protection when something goes wrong. An oxygen-deficient or toxic atmosphere can incapacitate a rescuer in seconds. That is why emergency and rescue arrangements (reg 5) are a legal duty that must be sorted before entry — non-entry rescue (a retrieval line on a tripod and winch) wherever possible, trained rescuers and the right equipment on site, and a plan that never relies on dialling 999 alone.
The order the law works in
- Avoid entry (reg 4(1)) — do the work from outside if it is reasonably practicable, by remote inspection, long-reach tools, or draining and cleaning from outside.
- Safe system of work (reg 4(2)) — if entry is unavoidable: test and monitor the atmosphere, ventilate, isolate and lock off inflows and energy, sort access and egress, communications, lighting, the right PPE/RPE and a posted attendant.
- Adequate emergency arrangements (reg 5) — in place before work starts.
These are concurrent duties, not a menu. Confined-space entry is normally controlled by an entry permit, and the decision to enter is made on site by a competent person — never from a web tool. This assessment helps you structure that thinking; it does not authorise entry.
Sources: the Confined Spaces Regulations 1997 and HSE's Approved Code of Practice L101 “Safe work in confined spaces” (see also hse.gov.uk/confinedspace).
RamsDocs helps draft structured RAMS from your job details. It does not replace competent-person review, site-specific judgement or your legal duties.
Need the full RAMS, not just the numbers?
Build the RAMS, add the site details, then review it before client submission.
Build a substance-by-substance COSHH assessment — hazards, exposure routes, controls, PPE/RPE and review dates.
Work through certification, gaps, intumescent and smoke seals, hinges, the self-closer, glazing and operation — critical defects flagged — and print an inspection record. Built around BS 8214 and the Fire Safety (England) Regulations 2022.
Work through the five-step fire risk assessment for non-domestic premises — fire hazards, people at risk and existing precautions, with critical gaps flagged — and print an FRA record. Built around the Regulatory Reform (Fire Safety) Order 2005; flags when a competent assessor is needed.
Found something wrong, out of date, or missing?